I run both a Neptune Apex and Neptune AC3.  Each covers features from the other so the critical tank paramters are duplicated.

Here is my Apex code as of 7/2013

FeedA = VorTech OFF
FeedB = Storm
FeedC = light/sound off (960 minutes)
FeedD = waterchange (30 minutes)


*************************************************************************
Program (19 line limit per outlet in 4.11 and earlier)
*************************************************************************
Default Outlet Limits (80 in 4.12, 128 in 4.20) per Apex
*************************************************************************

[ EmailAlm ] ( base_email )
Program Type: Advanced
Display Icon: Email
Program:
Set OFF
If Outlet TempAlm = ON Then ON
If Outlet CondtyAlm = ON Then ON
If Outlet pHAlm = ON Then ON
If Outlet PowerAlm = ON Then ON
If Outlet SumpHigh = ON Then ON
If Outlet SumpLow = ON Then ON
If Outlet ATOLow = ON Then ON
If Outlet ATOLong = ON Then ON
If Outlet DisplayHigh = ON Then ON
If Outlet SkimmerHigh = ON Then ON
If Outlet Pump = OFF Then ON
If Outlet Ozone = OFF Then ON
If Outlet HeaterAlm = ON Then ON
If Outlet ATOAlm = ON Then ON
If Outlet RtrnChmbrLow = ON Then ON
If Outlet WaterBug = ON Then ON
If Outlet PicoAWCLow = ON Then ON
If Outlet RefugLightLo = ON Then ON

[ Skimmer ] ( 4_1 )
Program Type: Advanced
Display Icon: Spiget
Program:
Fallback ON
Set ON
If Outlet SkimmerHigh = ON Then OFF
If Outlet SumpLow = ON Then OFF
If Outlet DisplayHigh = ON Then OFF
If Outlet Pump = OFF Then OFF
If Outlet RtrnChmbrLow = ON Then OFF
If Outlet HighTemp = ON Then OFF
If FeedC 000 Then OFF
If FeedD 001 Then OFF

[ Heater ] ( 4_2 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Fallback OFF
If TempSmp < 76.9 Then ON
If TempSmp > 77.3 Then OFF
If TempTnk > 77.4 Then OFF
If Outlet HeaterCall = ON Then OFF
If Outlet HeaterLong = ON Then OFF
Min Time 005:00 Then OFF

[ ATO ] ( 4_3 )
Program Type: Advanced
Display Icon: Spiget
Program:
Fallback OFF
OSC 005:00/000:11/030:00 Then ON
If Outlet ATOCall = OFF Then OFF
If Outlet ATOLow = ON Then OFF
If Outlet SumpHigh = ON Then OFF
If Outlet DisplayHigh = ON Then OFF
If Outlet Pump = OFF Then OFF
If Outlet CondvtyLo = ON Then OFF
If pHA1 < 07.40 Then OFF
If FeedD 001 Then OFF

[ DosePumpCa ] ( 4_4 )
Program Type: Advanced
Display Icon: Bars
Program:
Fallback OFF
Set OFF
If Time 01:00 to 01:12 Then ON
If Outlet Pump = OFF Then OFF
If pH > 08.25 Then OFF

[ RefugLight ] ( 4_5 )
Program Type: Advanced
Display Icon: Light A
Program:
Fallback OFF
Set OFF
If Outlet Refug = ON Then ON
If Outlet RefugLightON = ON Then ON
If Outlet RefugLightLo = ON Then OFF
If FeedC 001 Then OFF

[ DosePumpAlk ] ( 4_6 )
Program Type: Advanced
Display Icon: Bars
Program:
Fallback OFF
Set OFF
If Time 02:00 to 02:22 Then ON
If Outlet Pump = OFF Then OFF
If pH > 08.25 Then OFF

[ Pump ] ( 4_7 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback ON
Set ON
If Outlet SumpLow = ON Then OFF
If Outlet DisplayHigh = ON Then OFF
If FeedD 001 Then OFF

[ DosePumpMag ] ( 4_8 )
Program Type: Advanced
Display Icon: Bars
Program:
Fallback OFF
Set OFF
OSC 000:00/000:20/029:40 Then ON
If Time 00:30 to 23:59 Then OFF
If Outlet Pump = OFF Then OFF

[ SumpHigh ] ( Cntl:A1 )
Program Type: Advanced
Display Icon: Bell
Program:
If SwitchA1 OPEN Then ON
If SwitchA1 CLOSED Then OFF
Defer 000:10 Then ON
If FeedD 001 Then OFF

[ SumpLow ] ( Cntl:A2 )
Program Type: Advanced
Display Icon: Bell
Program:
If SwitchA2 OPEN Then ON
If SwitchA2 CLOSED Then OFF
Defer 000:20 Then ON
If FeedD 001 Then OFF

[ ATOCall ] ( Cntl:A3 )
Program Type: Advanced
Display Icon: Spiget
Program:
If SwitchA3 OPEN Then OFF
If SwitchA3 CLOSED Then ON
If Outlet ATOLong = ON Then OFF
Defer 001:00 Then ON

[ ATOLow ] ( Cntl:A4 )
Program Type: Advanced
Display Icon: Bell
Program:
If SwitchA4 OPEN Then ON
If SwitchA4 CLOSED Then OFF
Defer 000:10 Then ON

[ DisplayHigh ] ( Cntl:A5 )
Program Type: Advanced
Display Icon: Bell
Program:
If SwitchA5 OPEN Then ON
If SwitchA5 CLOSED Then OFF
Defer 000:15 Then ON

[ SkimmerHigh ] ( Cntl:A6 )
Program Type: Advanced
Display Icon: Bell
Program:
If SwitchA6 OPEN Then ON
If SwitchA6 CLOSED Then OFF
Defer 000:10 Then ON

[ HeaterLong ] ( Cntl:A7 )
Program Type: Advanced
Display Icon: Bell
Program:
Fallback OFF
If Outlet Heater = ON Then ON
If Outlet Heater = OFF Then OFF
Defer 160:00 Then ON

[ pHAlm ] ( Cntl:A8 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Set OFF
If pH < 07.87 Then ON
If pH > 08.40 Then ON
If pHPico < 07.83 Then ON
If pHPico > 08.40 Then ON

[ HighTemp ] ( Cntl:A9 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Set OFF
If TempSmp > 80.5 Then ON
Min Time 060:00 Then ON

[ HeaterCall ] ( Cntl:A10 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Set OFF
If TempSmp > 78.0 Then ON
If TempTnk > 78.0 Then ON

[ SunRise ] ( Cntl:A11 )
Program Type: Advanced
Display Icon: Sun
Program:
Set OFF
If Time 07:00 to 11:00 Then ON
If Outlet DayTime = ON Then OFF

[ DayTime ] ( Cntl:A12 )
Program Type: Advanced
Display Icon: Sun
Program:
Set OFF
If Time 11:00 to 15:30 Then ON

[ SunSet ] ( Cntl:A13 )
Program Type: Advanced
Display Icon: Sun
Program:
Set OFF
If Time 15:30 to 20:30 Then ON
If Outlet DayTime = ON Then OFF
If Outlet SunRise = ON Then OFF

[ Moon ] ( Cntl:A14 )
Program Type: Advanced
Display Icon: Moon
Program:
Set OFF
If Moon 000/000 Then ON
If Outlet SunRise = ON Then OFF
If Outlet DayTime = ON Then OFF
If Outlet Sun
Set = ON Then OFF

[ Refug ] ( Cntl:A15 )
Program Type: Advanced
Display Icon: Light A
Program:
Set OFF
If Time 18:00 to 08:00 Then ON

[ CondvtyHi ] ( Cntl:A16 )
Program Type: Advanced
Display Icon: Bars
Program:
Fallback OFF
Set OFF
If Condvty > 54.5 Then ON
Defer 001:00 Then ON

[ CondvtyLo ] ( Cntl:B1 )
Program Type: Advanced
Display Icon: Bars
Program:
Fallback OFF
Set OFF
If Condvty < 51.5 Then ON
Defer 001:00 Then ON

[ CondtyAlm ] ( Cntl:B2 )
Program Type: Advanced
Display Icon: Bars
Program:
Fallback OFF
Set OFF
If Outlet CondvtyHi = ON Then ON
If Outlet CondvtyLo = ON Then ON
Defer 001:00 Then ON

[ ATOLong ] ( Cntl:B3 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback OFF
If Outlet ATOCall = ON Then ON
If Outlet ATOCall = OFF Then OFF
Defer 045:00 Then ON
Min Time 015:00 Then ON

[ PowerAlmOff ] ( Cntl:B4 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
If Power Apex OFF 000 Then OFF
If Power Apex ON 000 Then ON
Defer 025:00 Then ON

[ PowerAlmOn ] ( Cntl:B5 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
If Power Apex OFF 000 Then OFF
If Power Apex ON 000 Then ON
If Outlet PowerAlmOff = ON Then OFF
Defer 015:00 Then ON

[ RtrnChmbrLow ] ( Cntl:B6 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
If Switchx6_1 OPEN Then ON
If Switchx6_1 CLOSED Then OFF
Defer 000:05 Then ON
If FeedD 001 Then OFF
Min Time 003:00 Then ON

[ HighHumid ] ( Cntl:B7 )
Program Type: Advanced
Display Icon: Left/Right Arrows
Program:
If Switchx6_3 OPEN Then OFF
If Switchx6_3 CLOSED Then ON
Defer 000:01 Then ON

[ VentCabnt ] ( Cntl:B8 )
Program Type: Advanced
Display Icon: Left/Right Arrows
Program:
Fallback OFF
OSC 005:00/020:00/035:00 Then ON

[ SumpFan ] ( Cntl:D1 )
Program Type: Advanced
Display Icon: Light A
Program:
Set OFF
If TempSmp > 77.5 Then ON
Min Time 020:00 Then OFF
If FeedC 000 Then OFF

[ OvrflwPmp ] ( Cntl:D2 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Set OFF

[ UV ] ( Cntl:D3 )
Program Type: Advanced
Display Icon: Spiget
Program:
Fallback OFF
Set OFF
If Outlet Pump = OFF Then OFF
Min Time 015:00 Then OFF

[ PicoHeater ] ( Cntl:D4 )
Program Type: Advanced
Display Icon: Spiget
Program:
Fallback OFF
If TmpPico < 76.9 Then ON
If TmpPico > 77.6 Then OFF
If Outlet PicoHtrLong = ON Then OFF
Min Time 005:00 Then OFF

[ Ozone ] ( Cntl:D5 )
Program Type: Advanced
Display Icon: Light A
Program:
Fallback OFF
Set OFF
If ORP < 360 Then ON
Defer 015:00 Then ON

[ CabinetVent ] ( Cntl:D6 )
Program Type: Advanced
Display Icon: Light A
Program:
Set OFF
If Outlet HighHumid = ON Then ON
If Outlet VentCabnt = ON Then ON
If Outlet SumpFan = ON Then ON
If FeedC 000 Then OFF

[ AirPump ] ( Cntl:D7 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback OFF
Set ON

[ PicoAWC ] ( Cntl:D8 )
Program Type: Advanced
Display Icon: Moon
Program:
Fallback OFF
Set OFF
If Time 08:00 to 08:09 Then ON
If Outlet PicoAWCLow = ON Then OFF

[ WaterBug ] ( Cntl:B9 )
Program Type: Advanced
Display Icon: Light A
Program:
Fallback OFF
If Switchx6_4 OPEN Then OFF
If Switchx6_4 CLOSED Then ON


[ BlueLED ] ( 3_5 )
Program Type: Advanced
Display Icon: Light A
Program:
Fallback OFF
Set OFF
If Outlet SunRise = ON Then BlueUp
If Outlet DayTime = ON Then BlueOn
If Outlet Sun
Set = ON Then BlueDn
If Outlet Storm = ON Then Weather
If Outlet CoralGlow = ON Then CoralGlo
If Outlet LED40percnt = ON Then LED40prc
If Outlet LED20percnt = ON Then LED20prc
If Outlet LED5percnt = ON Then LED5prc
If Outlet LED3percnt = ON Then LED3prc
If Outlet LED1percnt = ON Then LED1prc
If Outlet Picture = ON Then BluPictr
If FeedB 000 Then Weather
If FeedC 000 Then OFF

[ WhiteLED ] ( 3_6 )
Program Type: Advanced
Display Icon: Light B
Program:
Fallback OFF
Set OFF
If Outlet SunRise = ON Then WhiteUp
If Outlet DayTime = ON Then WhiteOn
If Outlet Sun
Set = ON Then WhiteDn
If Outlet Storm = ON Then Weather
If Outlet CoralGlow = ON Then CoralGlo
If Outlet LED40percnt = ON Then LED40prc
If Outlet LED20percnt = ON Then LED20prc
If Outlet LED5percnt = ON Then LED5prc
If Outlet LED3percnt = ON Then LED3prc
If Outlet LED1percnt = ON Then LED1prc
If Outlet Picture = ON Then WhtPictr
If FeedB 000 Then Weather
If FeedC 000 Then OFF

[ RoyalLED ] ( 3_7 )
Program Type: Advanced
Display Icon: Light A
Program:
Fallback OFF
Set OFF
If Outlet Moon = ON Then MoonLt
If Outlet SunRise = ON Then RoyalUp
If Outlet DayTime = ON Then RoyalOn
If Outlet Sun
Set = ON Then RoyalDn
If Outlet Storm = ON Then Weather
If Outlet CoralGlow = ON Then CoralGlo
If Outlet LED40percnt = ON Then LED40prc
If Outlet LED20percnt = ON Then LED20prc
If Outlet LED5percnt = ON Then LED5prc
If Outlet LED3percnt = ON Then LED3prc
If Outlet LED1percnt = ON Then LED1prc
If Outlet Picture = ON Then RylPictr
If FeedB 000 Then Weather
If FeedC 000 Then OFF

[ VortechRight ] ( 5_1 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback ReefCrst
Set ReefCrst
If Time 08:00 to 14:00 Then TidalSwl
If Time 15:30 to 15:35 Then ON
If Time 16:00 to 20:00 Then Nutrient
If Time 19:30 to 19:35 Then ON
If Time 22:00 to 06:00 Then Night
If Outlet VrtchFull = ON Then ON
If FeedA 000 Then OFF
If FeedD 000 Then OFF

[ VortechLeft ] ( 5_2 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback antiSync
Set antiSync
If Time 08:00 to 09:00 Then Sync
If Time 12:00 to 14:00 Then Sync
If Time 15:30 to 15:35 Then ON
If Time 16:00 to 20:00 Then Sync
If Time 19:30 to 19:35 Then ON
If Time 22:00 to 06:00 Then Sync
If Outlet VrtchFull = ON Then ON
If FeedA 000 Then OFF
If FeedD 000 Then OFF

[ VrtchFull ] ( Cntl:B10 )
Program Type: Advanced
Display Icon: Light B
Program:
Set OFF

[ PicoAWCLow ] ( Cntl:B11 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
If Switchx6_2 OPEN Then ON
If Switchx6_2 CLOSED Then OFF
Defer 000:10 Then ON

[ PicoHtrLong ] ( Cntl:B12 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback OFF
If Outlet PicoHeater = ON Then ON
If Outlet PicoHeater = OFF Then OFF
Defer 030:00 Then ON

[ LED40percnt ] ( Cntl:B13 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Fallback OFF
Set OFF

[ LED20percnt ] ( Cntl:B14 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Fallback OFF
Set OFF

[ LED5percnt ] ( Cntl:B15 )
Program Type: Advanced
Display Icon: Left/Right Arrows
Program:
Fallback OFF
Set OFF

[ LED3percnt ] ( Cntl:B16 )
Program Type: Advanced
Display Icon: Left/Right Arrows
Program:
Fallback OFF
Set OFF

[ LED1percnt ] ( Cntl:E1 )
Program Type: Advanced
Display Icon: Light A
Program:
Fallback OFF
Set OFF

[ PicoATOLow ] ( Cntl:E3 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
If Switchx6_6 OPEN Then ON
If Switchx6_6 CLOSED Then OFF
Defer 000:10 Then ON

[ RefugLightON ] ( Cntl:E4 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
If Switchx6_5 CLOSED Then ON
If Switchx6_5 OPEN Then OFF
Defer 000:01 Then ON

[ RefugLightLo ] ( Cntl:E5 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Fallback OFF
If Outlet RefugLightON = ON Then ON
If Outlet RefugLightON = OFF Then OFF
Defer 030:00 Then ON

[ CoralGlow ] ( Cntl:E6 )
Program Type: Advanced
Display Icon: Thermometer
Program:
Fallback OFF
Set OFF

[ Picture ] ( Cntl:E7 )
Program Type: Advanced
Display Icon: Left/Right Arrows
Program:
Fallback OFF
Set OFF

[ Storm ] ( Cntl:E8 )
Program Type: Advanced
Display Icon: Note
Program:
Set OFF
If Time 15:00 to 15:30 Then ON
If DoW SM-W-F- Then OFF

[ VortechQT ] ( 5_3 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback ReefCrst
Set ReefCrst
If Time 12:00 to 16:00 Then Constant
If Time 22:00 to 06:00 Then Night
If Outlet VrtchFull = ON Then ON
If FeedA 000 Then OFF
If FeedD 000 Then OFF

[ VortechMP10R ] ( 5_4 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback ReefCrst
Set ReefCrst
If Time 15:30 to 15:35 Then ON
If Time 19:30 to 19:35 Then ON
If Time 22:00 to 06:00 Then Night
If Outlet VrtchFull = ON Then ON
If FeedA 000 Then OFF

[ VortechMP10M ] ( 5_5 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback ReefCrst
Set ReefCrst
If Time 15:30 to 15:35 Then ON
If Time 19:30 to 19:35 Then ON
If Time 22:00 to 06:00 Then Night
If Outlet VrtchFull = ON Then ON
If FeedA 000 Then OFF

[ VortechMP10L ] ( 5_6 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback ReefCrst
Set ReefCrst
If Time 15:30 to 15:35 Then ON
If Time 19:30 to 19:35 Then ON
If Time 22:00 to 06:00 Then Night
If Outlet VrtchFull = ON Then ON
If FeedA 000 Then OFF

[ HeaterAlm ] ( Cntl:E9 )
Program Type: Advanced
Display Icon: Light A
Program:
Fallback OFF
Set OFF
If Outlet PicoHtrLong = ON Then ON
If Outlet HeaterLong = ON Then ON

[ ATOAlm ] ( Cntl:E10 )
Program Type: Advanced
Display Icon: Light B
Program:
Fallback OFF
Set OFF
If Outlet ATOLow = ON Then ON
If Outlet PicoATOLow = ON Then ON

[ PowerAlm ] ( Cntl:E11 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback OFF
Set OFF
If Power EB8_4 OFF 000 Then ON
If Power Apex OFF 000 Then ON
If Outlet PowerAlmOn = ON Then ON

[ TempAlm ] ( Cntl:E12 )
Program Type: Advanced
Display Icon: Up/Down Arrows
Program:
Fallback ON
Set OFF
If TempSmp > 80.5 Then ON
If TempSmp < 76.6 Then ON
If TempTnk > 80.5 Then ON
If TempTnk < 76.6 Then ON
If TempAir > 80.5 Then ON
If TempAir < 67.0 Then ON
If TmpPico > 80.5 Then ON
If TmpPico < 76.6 Then ON



PROFILES

[ Sync ] ( PF1 )
Type: Vortech
Vortech Type: Sync
Maximum Intensity: 40
Master Pump: VortechRight
[ antiSync ] ( PF2 )
Type: Vortech
Vortech Type: Anti-Sync
Maximum Intensity: 40
Master Pump: VortechRight
[ ReefCrst ] ( PF3 )
Type: Vortech
Vortech Type: Reef Crest
Maximum Intensity: 45
[ TidalSwl ] ( PF4 )
Type: Vortech
Vortech Type: Tidal Swell
Maximum Intensity: 45
[ Nutrient ] ( PF5 )
Type: Vortech
Vortech Type: Nutrient
Maximum Intensity: 45
[ Night ] ( PF6 )
Type: Vortech
Vortech Type: Constant
Maximum Intensity: 30
[ Slow ] ( PF7 )
Type: Vortech
Vortech Type: Constant
Maximum Intensity: 25
[ Constant ] ( PF8 )
Type: Vortech
Vortech Type: Constant
Maximum Intensity: 45
[ OnFull ] ( PF9 )
Type: Vortech
Vortech Type: Constant
Maximum Intensity: 100
[ BlueDn ] ( PF10 )
Type: Ramp
Ramp Time: 240
Start Intensity: 50
End Intensity: 1
[ BlueUp ] ( PF11 )
Type: Ramp
Ramp Time: 240
Start Intensity: 1
End Intensity: 50
[ BlueOn ] ( PF12 )
Type: Ramp
Ramp Time: 5
Start Intensity: 50
End Intensity: 55
[ MoonLt ] ( PF13 )
Type: Ramp
Ramp Time: 1
Start Intensity: 0
End Intensity: 1
[ RoyalDn ] ( PF14 )
Type: Ramp
Ramp Time: 240
Start Intensity: 50
End Intensity: 1
[ RoyalUp ] ( PF15 )
Type: Ramp
Ramp Time: 240
Start Intensity: 1
End Intensity: 50
[ RoyalOn ] ( PF16 )
Type: Ramp
Ramp Time: 5
Start Intensity: 50
End Intensity: 55
[ WhiteDn ] ( PF17 )
Type: Ramp
Ramp Time: 240
Start Intensity: 20
End Intensity: 1
[ WhiteUp ] ( PF18 )
Type: Ramp
Ramp Time: 240
Start Intensity: 1
End Intensity: 20
[ WhiteOn ] ( PF19 )
Type: Ramp
Ramp Time: 5
Start Intensity: 20
End Intensity: 25
[ Weather ] ( PF20 )
Type: Weather
Light Maximum Intensity: 25
Cloudy Light Intensity: 15
Cloud Duration: 5
Cloudy Time: 90
Probability of Lightning: 50
Lightning Intensity: 100
[ BlueWth ] ( PF21 )
Type: Ramp
Ramp Time: 0
Start Intensity: 25
End Intensity: 25
[ RoyalWth ] ( PF22 )
Type: Ramp
Ramp Time: 0
Start Intensity: 25
End Intensity: 25
[ WhiteWth ] ( PF23 )
Type: Ramp
Ramp Time: 0
Start Intensity: 25
End Intensity: 25
[ CoralGlo ] ( PF24 )
Type: Ramp
Ramp Time: 1
Start Intensity: 30
End Intensity: 30
[ LED40prc ] ( PF25 )
Type: Ramp
Ramp Time: 1
Start Intensity: 40
End Intensity: 40
[ LED20prc ] ( PF26 )
Type: Ramp
Ramp Time: 1
Start Intensity: 20
End Intensity: 20
[ LED5prc ] ( PF27 )
Type: Ramp
Ramp Time: 1
Start Intensity: 5
End Intensity: 5
[ LED3prc ] ( PF28 )
Type: Ramp
Ramp Time: 1
Start Intensity: 3
End Intensity: 3
[ LED1prc ] ( PF29 )
Type: Ramp
Ramp Time: 1
Start Intensity: 1
End Intensity: 1
[ BluPictr ] ( PF30 )
Type: Ramp
Ramp Time: 1
Start Intensity: 65
End Intensity: 65
[ WhtPictr ] ( PF31 )
Type: Ramp
Ramp Time: 1
Start Intensity: 60
End Intensity: 60
[ RylPictr ] ( PF32 )
Type: Ramp
Ramp Time: 1
Start Intensity: 65
End Intensity: 65


#####################

Neptune Apex, AC3, AC2 hidden calibration and diag menu


http://www.reefcentral.com/forums/showthread.php?t=696645


Now go to the hidden manual calibration menu. To do so go to the self test display. Press the up button twice, the down button twice, and then the select button. Select ORP manual cal.  Adjust the ORP offset up or down depending on the reading in the run display. For example say the ORP probe reads 390 instead of 400, then the ORP offset needs to be increase by 10. Leave the ORP scale unchanged since this is a single point calibration.